Version: 10.2.1c and 10.2.1c SP3 |
Fiber Manager Configuration > Configure Fiber Manager Reports |
Configure either the Flexible Patch Panel Connection Report OR the Original Patch Panel Connection Report.
Regardless of which Patch Panel Connection Report you elect to configure, you must assign the PATCHLOCATIONREPORTABLE class model name to the feature class representing patch locations. This model name enables you to select the patch location feature class when using the Patch Panel Connection Report tool.
While the Allocation Report does not require configuration, note that for the objects displayed in the report, their Primary Display Field setting determines the values in the Name fields and the values shown in the header row of the table. You can change the Primary Display field setting in the Field Display tab of the ArcFM Properties Manager.
You can customize your reports in Fiber Manager by adding one or more additional fields to each report. For example, in addition to the fields that appear in the Fiber Trace Report by default, you might also want to display attribute values from the Fiber Availability, Fiber Status, and Comments fields. Or, in the Splice Report, you may want to see Device Name values and the Tray on which fibers are spliced.
Add the following field model names to any field on any feature or object class. Use the field model name that corresponds to each report.
Fiber Allocation Report | FIBERALLOCATIONREPORTFIELD |
Fiber OTDR Trace Report | FIBEROTDRREPORTFIELD |
Fiber Circuit Trace Report | FIBERCIRCUITREPORTFIELD |
Patch Panel Connection Report | FIBERPPCONNFIELD |
Splice Report | FIBERSPLICEREPORTFIELD |
Fiber Trace Report | FIBERTRACEREPORTFIELD |
You can add the same field model name to multiple fields. The values in the fields to which these model names are assigned will appear so long as the corresponding object belongs in the fiber object hierarchy (e.g., Fiber Optic Cable > Buffer Tube > Fiber).